Ambient Temperature Range
Approvals & Certifications
- BAM
- CSA General-purpose Valve for Hazardous Location Class I/II, Div. 2, & Class III T4
- DNV GL (Formerly Germanischer Lloyd)
- EAC
- FDA
- FM Explosion-proof for Class I, Div. 1, & Dust-Ignition-proof for Class II/III, Div. 1, T4
- NAMUR
- UL Recognized, Listed General-purpose Valve
Consumption
- Power Consumption Frequency [AC (Operation), DC (Cold) Impulse (Inrush Winding)], DC (Cold): 11 W
- Power Consumption Frequency [DC (Warm) Impulse (Inrush Winding)], DC (Warm), AC (Operation): 8 W
- Power Consumption Frequency AC (Hold) Impulse (Inrush Winding): 20 VA
- Power Consumption Frequency AC (Hold): 15 VA
- Power Consumption Frequency AC (Inrush): 30 VA
Duty Cycle
- Duty Cycle for Brass, Stainless Steel & PVDF (ED for 5 W Version): 100 %
- Duty Cycle for PEEK: 60 % ED (40 % Intermittent Operation) in 30 minutes for 8 W Version
- Duty Cycle for PP: 40 % ED (60 % Intermittent Operation) in 30 minutes for 8 W Version
Electrical Connectors
- Moulded Cable or Terminal Box
- Tag Connector According to DIN EN 175301-803 Form A for Cable Plug Typical 2508/2509
Electrical Contacts
- Normally Closed
- Normally Open
Enclosure, Body Material
- 316 Stainless Steel, 1.4401
- Brass
- Metal
- PEEK
- Plastic
- Polypropylene (PP)
- PVDF (Polyvinylfluoride)
Environmental Protection
- IP65 with Cable Plug
- IP66
- IP67
- NEMA 250 4X
- Vibration-Proof
Flow Rate
- Water (AC) 50/60 Hz: 0.10 to 0.18 Kv (m³/hour) - Brass, Stainless Steel or PEEK Body
- Water (DC): 0.08 to 0.15 Kv (m³/hour) - Brass, Stainless Steel or PEEK Body
- Water: 0.1 to 0.18 Kv (m³/hour) - PVDF or PP Body
Materials of Construction
Mounting Position
- Preferably with Actuator Upright
Operating Voltages
- 120-240 V / 60 Hz
- 12-24 Vdc
- 24-230 V / 50 Hz
Orifice Size
- 0.078” to 0.157” (2 to 4 mm)
Pressure Range
- DC, Impulse - psi: 0 to 174 (kPa: 0 to 1,200, bar: 0 to 12) - PVDF or PP Body
- Impulse - psi: 0 to 232.1 (kPa: 0 to 1,600, bar: 0 to 16) - Brass, Stainless Steel or PEEK, PVDF or PP Body (AC) 50 or 60 Hz
- Vacuum - psi: -14.21 to 145 (kPa: -98 to 1,000, bar: -0.98 to 10)
Process Temperature
- 0° to 80° C (32° to 176° F) for Body Material Brass, Stainless Steel or PEEK (NBR), PP or PVDF (NBR, FKM)
- EPDM: -30° to 80° C (-22° to 176° F) for Body Material PP or PVDF
- EPDM: -30° to 90° C (-22° to 194° F) for Body Material Brass, Stainless Steel or PEEK
- FFKM: 5° to 80° C (41° to 176° F) for Body Material PP or PVDF
- FFKM: 5° to 90° C (41° to 194° F) for Body Material Brass, Stainless Steel or PEEK
- FKM: 0° to 90° C (32° to 194° F) for Body Material Brass, Stainless Steel or PEEK
Response Time
- Frequency AC Opening, Closing: 8 to 15 milliseconds
- Frequency DC Opening, Closing: 10 to 20 milliseconds
Seat / Seal Material
- Seal: EPDM (Medium: Alkalis, Acids to Medium Concentrations, Alkaline Washing & Bleaching Lyes)
- Seal: FFKM (Medium: Aggressive Mediums, Hot Air, Hot Oils)
- Seal: FKM (Medium: Oxydizing Acids & Substances, Hot Oils with Additives, Salt Solutions, Waste Gases, Oxygen)
- Seal: NBR (Medium: Neutral Medium Such as Compressed Air, Town Gas, Water, Hydraulic Oil, Oils & Greases without Additives, Oxygen)
- Seat: 316 Stainless Steel, 1.4401
- Seat: Brass
- Seat: PEEK
- Seat: Polypropylene (PP)
- Seat: PVDF (Polyvinylfluoride)
Tolerance
- Voltage Tolerance: ± 10 %