0331 2/2 or 3/2-Way Pivoted Armature Valve

Brand: Burkert Fluid Control Systems

The 0331 valve is a direct-acting, media-separated pivoted armature valve. It is available in 3/2 and 2/2-way versions. As a 3/2-way version, it can be used as a distributor or mixing valve.

Various diaphragm material combinations and methods of operation are available depending on the application. The standard brass housing satisfies all European drinking water requirements. Stainless steel (316L), PVDF, polypropylene and PEEK housing versions complete the offering. The solenoid coils are moulded with a chemically resistant epoxy. The 0331 is equipped with manual override for commissioning and testing.

For reduced energy requirements all coils can be delivered with electronic power reduction or as an impulse version.

The switching status can be indicated with position feedback as a binary or NAMUR signal. In combination with a plug in accordance with DIN EN 17301-803 Form A, the valves satisfy protection class IP65/67 - in combination with a stainless steel or plastic housing NEMA 250 Kat.4X.

Features: 
  • Direct acting, medium separated valve up to orifice DN 4
  • Maintenance-free pivoted armature technology
  • Vibration resistant, screwed block coil system
  • Suitable for aggressive alkali solutions and acids
  • Service friendly, robust manual override
  • Explosion proofed version

Specifications

Actuator Type

  • Direct-Acting

Ambient Temperature Range

  • Maximum

Approvals & Certifications

  • BAM
  • CSA General-purpose Valve for Hazardous Location Class I/II, Div. 2, & Class III T4
  • DNV GL (Formerly Germanischer Lloyd)
  • EAC
  • FDA
  • FM Explosion-proof for Class I, Div. 1, & Dust-Ignition-proof for Class II/III, Div. 1, T4
  • NAMUR
  • UL Recognized, Listed General-purpose Valve

Consumption

  • Power Consumption Frequency [AC (Operation), DC (Cold) Impulse (Inrush Winding)], DC (Cold): 11 W
  • Power Consumption Frequency [DC (Warm) Impulse (Inrush Winding)], DC (Warm), AC (Operation): 8 W
  • Power Consumption Frequency AC (Hold) Impulse (Inrush Winding): 20 VA
  • Power Consumption Frequency AC (Hold): 15 VA
  • Power Consumption Frequency AC (Inrush): 30 VA

Diaphragm Material

  • EPDM
  • FFKM
  • FKM
  • NBR

Duty Cycle

  • Duty Cycle for Brass, Stainless Steel & PVDF (ED for 5 W Version): 100 %
  • Duty Cycle for PEEK: 60 % ED (40 % Intermittent Operation) in 30 minutes for 8 W Version
  • Duty Cycle for PP: 40 % ED (60 % Intermittent Operation) in 30 minutes for 8 W Version

Electrical Connectors

  • Moulded Cable or Terminal Box
  • Tag Connector According to DIN EN 175301-803 Form A for Cable Plug Typical 2508/2509

Electrical Contacts

  • Normally Closed
  • Normally Open

Enclosure, Body Material

  • 316 Stainless Steel, 1.4401
  • Brass
  • Metal
  • PEEK
  • Plastic
  • Polypropylene (PP)
  • PVDF (Polyvinylfluoride)

Environmental Protection

  • IP65 with Cable Plug
  • IP66
  • IP67
  • NEMA 250 4X
  • Vibration-Proof

Flow Rate

  • Water (AC) 50/60 Hz: 0.10 to 0.18 Kv (m³/hour) - Brass, Stainless Steel or PEEK Body
  • Water (DC): 0.08 to 0.15 Kv (m³/hour) - Brass, Stainless Steel or PEEK Body
  • Water: 0.1 to 0.18 Kv (m³/hour) - PVDF or PP Body

Insulation

  • Coil Insulation Class H

Materials of Construction

  • Coil: Epoxy

Mounting Position

  • Preferably with Actuator Upright

O-Ring Material

  • EPDM
  • FFKM
  • FKM
  • NBR

Operating Voltages

  • 120-240 V / 60 Hz
  • 12-24 Vdc
  • 24-230 V / 50 Hz

Orifice Size

  • 0.078” to 0.157” (2 to 4 mm)

Override

  • Manual Override

Pressure Range

  • DC, Impulse - psi: 0 to 174 (kPa: 0 to 1,200, bar: 0 to 12) - PVDF or PP Body
  • Impulse - psi: 0 to 232.1 (kPa: 0 to 1,600, bar: 0 to 16) - Brass, Stainless Steel or PEEK, PVDF or PP Body (AC) 50 or 60 Hz
  • Vacuum - psi: -14.21 to 145 (kPa: -98 to 1,000, bar: -0.98 to 10)

Process Temperature

  • 0° to 80° C (32° to 176° F) for Body Material Brass, Stainless Steel or PEEK (NBR), PP or PVDF (NBR, FKM)
  • EPDM: -30° to 80° C (-22° to 176° F) for Body Material PP or PVDF
  • EPDM: -30° to 90° C (-22° to 194° F) for Body Material Brass, Stainless Steel or PEEK
  • FFKM: 5° to 80° C (41° to 176° F) for Body Material PP or PVDF
  • FFKM: 5° to 90° C (41° to 194° F) for Body Material Brass, Stainless Steel or PEEK
  • FKM: 0° to 90° C (32° to 194° F) for Body Material Brass, Stainless Steel or PEEK

Response Time

  • Frequency AC Opening, Closing: 8 to 15 milliseconds
  • Frequency DC Opening, Closing: 10 to 20 milliseconds

Seat / Seal Material

  • Seal: EPDM (Medium: Alkalis, Acids to Medium Concentrations, Alkaline Washing & Bleaching Lyes)
  • Seal: FFKM (Medium: Aggressive Mediums, Hot Air, Hot Oils)
  • Seal: FKM (Medium: Oxydizing Acids & Substances, Hot Oils with Additives, Salt Solutions, Waste Gases, Oxygen)
  • Seal: NBR (Medium: Neutral Medium Such as Compressed Air, Town Gas, Water, Hydraulic Oil, Oils & Greases without Additives, Oxygen)
  • Seat: 316 Stainless Steel, 1.4401
  • Seat: Brass
  • Seat: PEEK
  • Seat: Polypropylene (PP)
  • Seat: PVDF (Polyvinylfluoride)

Solenoid Type

  • 2/2-Way
  • 3/2-Way

Tolerance

  • Voltage Tolerance: ± 10 %

Viscosity

  • Maximum
show more