Burkert’s inductive conductivity meter type 8228 is designed for usage under harsh conditions in many industrial processes for measuring in concentrated liquids like acids, caustics or salt-solutions over a wide measuring range.
Features
  • Perfect for concentrated liquids and wide conductivity range
  • Pre-parameterized versions available for direct start-up
  • Integral device for direct connection to PLC
  • Simulation of process values for diagnostics
  • Sensor available in PP, PVDF or PEEK

Specifications

Accuracy

  • Uncertainty of the Output Value: 1 % of Full Scale

Ambient Temperature Range

  • Operating & Storage: -10° to 60° C (14° to 140° F)

Approvals & Certifications

  • ECR 1935/2004
  • CE
  • CIP Version: FDA
  • EU Directives
  • PED 2014/68/EU
  • UL (C,US): UL 61010-1 + CAN/CSA C22.2 No.61010-1

BSP Connection

  • G 2”

Circuit Protection

  • Short Circuit Protected

Consumption

  • Current: ≤ 25 mA (At 12 Vdc & without the Consumption of the 4-20 mA Output)

Cover Material

  • Polycarbonate (PC)

Current

  • 3-Wire: 4-20 mA

Diameter

  • Connection Cable: 0.12” to 0.25” (3 to 6.5 mm)

Electrical Connectors

  • 2 Outputs Meter (3-Wire): 1 x 5-Pin M12 Male Fixed Connector
  • 4 Outputs Meter (3-Wire): 1 x 5-Pin M12 Male & 1 x 5-Pin M12 Female Fixed Connectors
  • Maximum
  • Shielded Cable

Electrical Protection

  • Voltage Peak: Protected

Enclosure, Body Material

  • 316L Stainless Steel
  • PPS

Environmental Protection

  • IP65
  • IP67

Humidity

  • Maximum

Linearity

  • Conductivity Measurement: ± 2 %

Loop Impedance

  • 1,100 ohms at 36 Vdc, Max.
  • 100 ohms at 12 Vdc, Max.
  • 610 ohms at 24 Vdc, Max.

Materials of Construction

  • Display: Polycarbonate (PC)
  • Navigation Key: PBT
  • With CIP Version (M12 Fixed Connectors), Fixed Connector Holder: 316L Stainless Steel
  • With Standard Version (M12 Fixed Connectors): Brass Nickel-Plated

Measuring Error

  • Conductivity Measurement Deviation: ± (2 % of the Measured Value + 5 µS/cm)
  • Temperature Measurement Deviation: ± 1° C (1.8° F)

Measuring Range

  • Conductivity Measurement: 10 to 2,000,000 µS/cm

Nut & Bolt Material

  • With Standard Version (Nut): Polycarbonate (PC)

Output

  • 4-20 mA
  • Transistor (NPN): 1-36 Vdc
  • Transistor (PNP & NPN): 700 mA - Max.

Pipe Connection

  • DN 100 Pipe
  • DN 125 Pipe
  • DN 15 Pipe
  • DN 150 Pipe
  • DN 20 Pipe
  • DN 200 Pipe
  • DN 25 Pipe
  • DN 32 Pipe
  • DN 40 Pipe
  • DN 50 Pipe
  • DN 65 Pipe
  • DN 80 Pipe

Pressure Range

  • PEEK - psi: 0 to 145 (kPa: 0 to 1,000, bar: 0 to 10)
  • PP, PVDF - psi: 0 to 87 (kPa: 0 to 600, bar: 0 to 6)

Process Connection Material

  • With CIP Version: 316L Stainless Steel

Process Temperature

  • PEEK: -15° to 130° C (5° to 266° F)
  • PP: 0° to 80° C (32° to 176° F)
  • PVDF: -15° to 100° C (5° to 212° F)

Repeatability

  • Conductivity Measurement: ± (0.2 % of the Measured Value + 2 µS/cm)

Resolution

  • Conductivity Measurement: 0.1 µS/cm
  • Temperature Measurement: 0.1° C (0.18° F)

Response Time

  • 10 to 90 %: 150 milliseconds
  • Conductivity Measurement (t90): 3 to 40 seconds

Reverse Polarity Protection

  • Protected Against Reverse Polarity

Screw Material

  • Stainless Steel

Seat / Seal Material

  • Seal: Silicone
  • With Standard Version & with CIP Version (Seal): EPDM
  • With Standard Version & with CIP Version (Seal): FKM

Sensor, Probe Type

  • Integrated Sensor

Supply Voltage

  • 12-36 Vdc ± 10 % Oscillation Rate, Filtered & Regulated

Switch Type

  • Transistor (PNP or NPN)

Temperature Range

  • Measuring Range: -15° to 130° C (5° to 266° F)

Tri-Clamp Connection

  • 1-1/2” Tri-Clamp
  • CIP Version: 2” Tri-Clamp

Wetted Materials

  • With CIP Version (Sensor Holder): 316L Stainless Steel
  • With Standard Version & with CIP Version (Sensor Holder): PEEK
  • With Standard Version & with CIP Version (Sensor Holder): PVDF
  • With Standard Version (Sensor Holder): Polypropylene (PP)