SE56 Transmitter for Electromagnetic Flow Sensor

Brand: Burkert Fluid Control Systems

The electronics Type SE56 (blind in compact version or with display in compact or remote version) connected to the magnetic flow sensor fitting Type S051, S054, S055 or S056 is designed for applications with liquids with a minimum conductivity of 5 µS/cm. The device can be parameterize either with 3 keypads (version with display) or by computer via a serial interface. 

As standard, the equipment is supplied with one or two transistor outputs and one digital input. As options, other features are available: such as high frequency output, current output, PROFIBUS DP, HART.

Specifications

Ambient Temperature Range

  • Operating & Storage: -20° to 40° C (-4° to 104° F) - SE56 Blind
  • Operating & Storage: -20° to 60° C (-4° to 140° F) - SE56 Standard with Display
  • Operating: -10° to 50° C (14° to 122° F) - SE56 Basic
  • Storage: -20° to 50° C (-4° to 122° F) - SE56 Basic

Approvals & Certifications

  • CE
  • EU

Cable Length

  • 20 metres, Max.

Communication

  • HART - SE56 Standard with Display
  • PROFIBUS DP - SE56 Standard with Display & SE56 Blind
  • RS-232 - SE56 Standard with Display
  • RS-485

Consumption

  • Power: 10 W, Max.
  • Power: 25 VA, Max.
  • Power: 6 W, Max.

Cover Material

  • Polyphenylene Sulfide (PPS) - SE56 Blind

Display

  • Alphanumeric Display 2 Lines x 16-Characters, without Back Light - SE56 Basic
  • Graphic Display 8 Lines x 16-Characters, 128 x 64 Pixels with Back Light - SE56 Standard with Display

Electrical Connectors

  • 2 Cable Glands PG9 - SE56 Blind
  • 3 Cable Glands PG11 - SE56 Basic
  • 6 Cable Glands PG11 - SE56 Standard with Display

Enclosure, Body Material

  • 304 Stainless Steel Electro-Polish - SE56 Standard with Display
  • Die Casting Aluminum - SE56 Standard with Display
  • Nylon
  • Polyamide 6 (PA6) with Glass Fiber - SE56 Basic
  • Stainless Steel - Electronics SE56 Blind

Environmental Protection

  • IP65 - SE56 Basic
  • IP67 - SE56 Standard with Display & SE56 Blind

Frequency

  • 1,250 Hz

Function

  • Batch Function - SE56 Standard with Display & SE56 Blind
  • Bi-Directional Measure
  • Diagnostic Function
  • Dual Measurement Range - SE56 Standard with Display
  • Empty Pipe Detection
  • Plug in (Protected Plug for Connection to PC or Hand Terminal) - SE56 Basic
  • Remote Configuration (For Connection to PC or Hand Terminal through Remote Configuration Tool Kit) - SE56 Standard with Display & SE56 Blind

Humidity

  • ≤ 85 % Relative Humidity, Non-Condensing

Isolation

  • Galvanically Isolated (All the Input/Outputs are Galvanically Isolated from Power Supply)

Load Resistance

  • 1,000 ohms - SE56 Standard with Display
  • 800 ohms Passive - SE56 Blind & SE56 Basic

Mounting

  • Wall Mounted

Output

  • 4-20 mA
  • Pulse: 100 mA
  • Pulse: 40 Vdc

Output Format

  • Open Collector

Power Supply

  • 12-60 Vdc - SE56 Basic
  • 20-30 Vdc - SE56 Blind
  • 90-265 Vac - SE56 Standard with Display (44 to 66 Hz) & SE56 Basic

Repeatability

  • ± 0.1 % of Reading - SE56 Standard with Display & SE56 Blind
  • ± 0.2 % of Reading - SE56 Basic

Seat / Seal Material

  • Seal: EPDM - SE56 Blind

Tolerance

  • Flow Rate (Volume): ± 0.05 % of Reading - SE56 Standard with Display
  • Flow Rate (Volume): ± 0.1 % of Reading - SE56 Basic
  • Output 4-20 mA, Frequency Output: ± 0.08 % of Reading - SE56 Standard with Display
  • Output 4-20 mA, Frequency Output: ± 0.12 % of Reading - SE56 Basic
show more