Ambient Temperature Range
Applications
- Gas Control, Welding Equipment
- Neutral Gases & Liquids
- Pneumatic Control
- Shut-Off, Dosing, Filling & Ventilating
- Small Scale Instruments, Laboratory & Measuring Equipment
- Vacuum
Consumption
- Power Consumption (AC Hold): 6 VA / 4 W
- Power Consumption (AC Inrush): 9 VA
- Power Consumption (DC): 4 W or 2 W Depending on Version
Cycling Rate
- 1,000 cycles/minute - Actuator
Duty Cycle
- 100 % Continuous Rating for Manifold Assembly Use Reduced Switch-On Time or 2 W Version - Actuator
Electrical Connectors
- Plug Connection without Cable Plug
Environmental Protection
- Rating with Cable Plug, Cable or Lead: IP65 - Actuator
Flow Rate
- Air: 33 to 65 QNn (L/min) [Measured with bar: 6 Upstream Pressure & bar: 1 Pressure Drop Across the Valve at 20° C (68° F)]
- Water: 0.030 to 0.060 Kv (m³/hour)
Mounting Position
- Preferably with Solenoid System Upright
Operating Voltages
- 12-24 Vdc
- 24-240 V / 50 Hz
Orifice Size
- 0.039” to 0.062” (1 to 1.6 mm)
Pressure Range
- psi: 0 to 145 (kPa: 0 to 1,000, bar: 0 to 10) [Also Suitable for Vacuum]
Response Time
- Closing: 8 milliseconds
- Opening: 12 milliseconds
Seat / Seal Material
- Seal: NBR (Fluids Handled: Neutral Fluids, Compressed Air, Water, Hydraulic Oil, Oils & Fat without Additives, Town Gas) - Valve
- Seat: Brass
- Seat: Polyamide
Temperature Range
- EPDM: -40° to 90° C (-40° to 194° F)
- FPM: -10° to 100° C (14° to 212° F)
- NBR: -10° to 90° C (14° to 194° F)
Tolerance
- Voltage Tolerance: ± 10 % - Actuator