Adjustment Type
- External Ground Screw
- Factory Set (Pre-Set)
Ambient Temperature Range
- -50° to 80° C (-58° to 176° F) - Set Point Shifts less than 1 % of Range for a 28° C (50° F) Ambient Temperature Change
Applications
- Chemical Plants & Refineries
- Instrument Panels
- Offshore Platforms
- Rotating Equipment
Approvals & Certifications
- ABNT NBR IEC 60079-0, 60079-1, 60079-31 Certificate # UL-BR 15.0174X
- ATEX Directive 94/9/EC II 1 G Ex ia IIC T6 Ga Tamb: -50° to 60° C (-58° to 140° F) UL International Demko A/S (N.B.# 0539) Certificate # Demko 11-ATEX-1105261X EN 60079-0, 60079-11, 60079-26
- ATEX Directive 94/9/EC II 2 G Ex d IIC T6 Gb II 2 D Ex Tb IIIC T85° C (185° F) Db Tamb: -50° to 80° C (-58° to 176° F) UL International Demko A/S (N.B.# 0539) Certificate # Demko 08-ATEX-0717128X EN 60079-0, 60079-1, 60079-31
- CE
- CRN
- CSA C22.2 No. 14, 25 & 30 - File # E40857
- Dual Seal Certified to ANSI/ISA 12.27.01 (Meets CEC & NEC Secondary Seal Requirements) Standard on Straight
- EAC Flameproof Junction Box, Pre-Wired
- Ex ia IIC T6 Ga Tamb. = -50° ≤ Tamb ≤ 60° C IEC 60079-0, 60079-11 Certificate # IECEx UL 14.0075X
- GOST-R 0Ex ia IIC T6 Ga x Tamb: -50° to 60° C (-58° to 140° F)
- GOST-R 1Ex d IIC T6 Gb x Tamb: -50° to 80° C (-58° to 176° F) NANIO CCVE Certification Center Certificate # RU C-US.ГБ05.B.01185 ГOCT P MЭК 60079-0, 60079-11, 60079-1, 60079-31, ГOCT 31610.26, IEC 60079-26
- GOST-U 1 ExdIICT6X Tamb: -56° to 85° C (-68.8° to 185° F) SVODOTSTVO #719 by DVSTS VE (TCCExEE)
- IEC Ex Certified Ex d IIC T6 Gb Ex Tb IIIC T85° C (185° F) Db IP66 Tamb. = -50° to 80° C (-58° to 176° F) IEC 60079-0, 60079-1, 60079-31 IEC 60079-0, 60079-1, 60079-31 Certificate # IECEx UL 14.0072X
- INMETRO Ex d IIC T6 Gb Ex Tb IIIC T85° C Db IP66 -50° C ≤ Tamb ≤ 80° C
- Low Voltage Directive (LVD) 2006/95/E
- PESO Ex ia IIC T6 Ga Tamb: -50° to 60° C (-58° to 140° F) UL International Demko A/S (N.B.# 0539) Certificate # P305465 / 1 EN 60079-0, 60079-11, 60079-26
- PED: 97/23/E
- UL (C,US) 508 & 1203, Class I, Div. 1 & 2, Groups A, B, C, D Class II, Div. 1 & 2, Groups E, F, G Class III Class I, Zone 1, Group IIC Enclosure Typical 4X
Approvals & Certifications
Deadband
- Inches Hg: 0.2 to 2
- Inches WC: 0.5 to 10
- psi: 0.01 to 0.361 (kPa: 0.124 to 2.491, Mbar: 1.2 to 24.9)
Electrical Connectors
- 1/2” NPT Male with 72” Leadwires
- 4-Terminal DIN Connector (DIN 43650 Form A)
- Common
- Junction Box
- M20 Metric Threads, 72” Leads
Electrical Contacts
- Bifurcated Gold Contacts
- Normally Closed
- Normally Open
- Silver
Electrical Rating
- 1 A at 125 Vac, 1 A Resistive & 0.5 A Inductive at 28 Vdc
- 5 A at 125/250 Vac, 5 A Resistive & 3 A Inductive at 28 Vdc
Environmental Protection
- Flameproof
- Intrinsically Safe
- IP66
- Typical 4X
- Typical 7
- Typical 9
- Vibration-Proof
Name Plate, Tag Material
- Paper, Stainless Steel ID Tag & Wire Attachment, Text Limited to 2 Lines of 25-Characters Each, Max.
NPT Connection
- 1/2” NPT Female
- 1/4” NPT Female
Overpressure & Static Pressure Limits
- Over Range Pressure - psi: 75 (kPa: 517.1, bar: 5.2)
Process Connection Material
Process Temperature
- -18° to 93° C (0° to 200° F)
- -7° to 121° C (20° to 250° F) for Viton Sensor
Proof Pressure
- psi: 100 (kPa: 689.5, bar: 6.9)
Repeatability
- Set Point Repeatability: ± 1 % of Adjustable Range
Service
- Oxygen Service Cleaned in Accordance with ASTM G93, Verification Typical 1, Tests 1 through 3
Set Point - Decreasing
- bar: -1 to 13.8
- Inches Hg: -30 to 0
- Inches WC: -20 to 200
- kPa: -101.4 to 1,379
- psi: -14.7 to 200
Set Point - Increasing
- bar: -1 to 13.8
- Inches Hg: -30 to 0
- Inches WC: -20 to 200
- kPa: -101.4 to 1,379
- psi: -14.7 to 200
Shock
- Set Point Repeats after 75 G, 10 milliseconds
Storage Temperature
- -50° to 80° C (-58° to 176° F)
Switch Type
- One SPDT, Hermetically Sealed
- Two SPDT for DPDT Action, Hermetically Sealed
System Pressure
- bar: 0 to 5.171
- kPa: 0 to 517.1
- psi: 0 to 75
Vibration
- Set Point Repeats after 15 G, 10 to 2000 Hz