Accuracy
- High-Accuracy Density: ± 0.0005 G/mL
Ambient Temperature Range
- -40°C to 55°C (-40°F to 131°F)
Approvals & Certifications
- ATEX: 94/9/EC, EN 60079-0: 2012, EN 60079-1: 2007, EN 60079-11: 2012
- CSA: Class I, Zone 1, Ex d Ib IIB T4 Gb, Class I, Zone 1, Ex d [ib] IIB T6 Gb
- EMC Directive: 2004/108/EC, EN 55011: 1998, A1, 1999, A2: 2002, Group 1, Class B, EN 61000-6-2: 2001, EN061326-1: 2006
- IEC Ex: IEC 60079-0: 2011, IEC 60079-1: 2007-04, IEC 60079-11: 2011
Configuration
- Integral - Transmitter
- Separately Mounted - Transmitter
Damping Adjustment
- Density: 4 seconds
- Flow Rate: 0.8 second
- Temperature: 2.5 seconds
Density Range
- 0.3 to 2 G/mL - Metering Range (Liquid)
Display
- 128 x 64 Dots LCD
- Backlit
- LCD & LED
Electrical Connectors
- Minimum Conductor Size: 18 AWG
Enclosure Finish
- Paint Color: Light Gray (RAL7035)
- Paint Typical: Baked Enamel
Flange Size - 1” (DN 25)
- 1” (DN 25) - 150# ASME
- 1” (DN 25) - 300# ASME
- 1” (DN 25) - 600# ASME
- 1” (DN 25) - 900# ASME
- 1” (DN 25) - PN 10
- 1” (DN 25) - PN 16
- 1” (DN 25) - PN 25
- 1” (DN 25) - PN 40
Flange Size - ½” (DN 15)
- ½” (DN 15) - 150# ASME
- ½” (DN 15) - 300# ASME
- ½” (DN 15) - 600# ASME
- ½” (DN 15) - 900# ASME
- ½” (DN 15) - PN 16
- ½” (DN 15) - PN 25
- ½” (DN 15) - PN 40
- ½” (DN 15) - PN 10
Flange Size - 10” (DN 250)
- 10” (DN 250) - 150# ASME
- 10” (DN 250) - 300# ASME
- 10” (DN 250) - 600# ASME
- 10” (DN 250) - PN 10
- 10” (DN 250) - PN 16
- 10” (DN 250) - PN 25
- 10” (DN 250) - PN 40
Flange Size - 1½” (DN 40)
- 1½” (DN 40) - 150# ASME
- 1½” (DN 40) - 300# ASME
- 1½” (DN 40) - 600# ASME
- 1½” (DN 40) - 900# ASME
- 1½” (DN 40) - PN 10
- 1½” (DN 40) - PN 16
- 1½” (DN 40) - PN 25
- 1½” (DN 40) - PN 40
Flange Size - 2” (DN 50)
- 2” (DN 50) - 150# ASME
- 2” (DN 50) - 300# ASME
- 2” (DN 50) - 600# ASME
- 2” (DN 50) - 900# ASME
- 2” (DN 50) - PN 10
- 2” (DN 50) - PN 16
- 2” (DN 50) - PN 25
- 2” (DN 50) - PN 40
Flange Size - 3” (DN 80)
- 3” (DN 80) - 150# ASME
- 3” (DN 80) - 300# ASME
- 3” (DN 80) - 600# ASME
- 3” (DN 80) - 900# ASME
- 3” (DN 80) - PN 10
- 3” (DN 80) - PN 16
- 3” (DN 80) - PN 25
- 3” (DN 80) - PN 40
Flange Size - 4” (DN 100)
- 4” (DN 100) - 300# ASME
- 4” (DN 100) - 600# ASME
- 4” (DN 100) - PN 10
- 4” (DN 100) - PN 16
- 4” (DN 100) - PN 25
- 4” (DN 100) - PN 40
- 4” (DN 100) 150# ASME
Flange Size - 6” (DN 150)
- 6” (DN 150) - 150# ASME
- 6” (DN 150) - 300# ASME
- 6” (DN 150) - 600# ASME
- 6” (DN 150) - PN 10
- 6” (DN 150) - PN 16
- 6” (DN 150) - PN 25
- 6” (DN 150) - PN 40
Flange Size - 8” (DN 200)
- 8” (DN 200) - 150# ASME
- 8” (DN 200) - 300# ASME
- 8” (DN 200) - 600# ASME
- 8” (DN 200) - PN 10
- 8” (DN 200) - PN 16
- 8” (DN 200) - PN 25
- 8” (DN 200) - PN 40
Flow Rate
- 0.00088 to 514 lbs/min - Guaranteed Minimum Mass Flow Rate
- 0.0044 to 2572 lbs/min - Minimum Setting of Mass Flow Rate
- 0.088 to 51441 lbs/min - Maximum
- 0.132 to 102883 lbs/min - Maximum
Mounting Position
- Horizontal Piping
- Vertical Piping
NPT Connection
- ½” NPT Female
- ¼” NPT Female
- ¾” NPT Female
Operating Pressure
- psi: 142 (kPa: 979, bar: 9.79) - Maximum
- psi: 2,176 (kPa: 15,000, bar: 150) - Maximum
Output
- 10-30 V, 50 mA DC - Open Collector Pulse Output
- 4-20 mA DC, Maximum
Output Impedence
- 2.2 kiloohms - Pulse Output
Power Supply
- 20-30 Vdc
- 85-264 Vac, 50/60 Hz
Pressure Range
- psig: 203 to 1,044 (kPa: 1,400 to 7,198, bar: 14 to 71.98) - Sensor Housing Withstand
Range
- Transmission Length of Separately-Mounted: 656 feet (200 metres)
- Transmission Length: up to 3937 feet (1,200 metres) at 100 Hz
Repeatability
- ± 0.05 % of Reading ( ±½ ZS) at Liquids
- ± 0.1 % of Reading ( ±½ ZS) at Liquids
- ± 0.25 % of Reading ( ±½ ZS) at Gases
Resistance
- Pulse Ouput ON Resistance: ≤ 0.6 ohm
- Status Output ON Resistance: ≥ 0.6 ohm
Rotation
- Bi-Directional - Flow Direction
Stability
- 0.000013 to 2.572 lbs/min - Zero Stability
Temperature Range
- -200°C to 200°C (-328°F to 392°F)
Tri-Clamp Connection
- 1” IDF Ferrule
- ½” IDF Ferrule
- 1½” IDF Ferrule
- 2” IDF Ferrule
- 3” IDF Ferrule
Uncertainty
- ± 0.003 G/mL - Uncertainty of Density (Liquid)
- ± 0.1 % of Full Scale - Analog Output Uncertainty
- ± 0.2 % of Reading ( ± Zero Stability) - Uncertainty of Flow Rate (Liquid)
- ± 0.5 % of Reading ( ± Zero Stability) - Uncertainty of Flow Rate (Gas)
Wetted Materials
- 316L Stainless Steel
- Alloy C-22 (Hastelloy)