Ambient Temperature Range
Applications
- Aggressive Fluids
- Disinfectants & Preserving Fluids
- Food Processing
- For De-ionized Water
- Liquid & Gaseous Fluids
- Medical Technology
- Solvents
- Ultra-Pure Fluids
Approvals & Certifications
Consumption
- Power Consumption: 4 W - Actuator
Current
- Cable Plug (Continuous Current): Max.
Cycling Rate
- 0 to 300 cycles/minute - Actuator
Diameter
- Cable Diameter: 0.171” to 0.281” (4.34 to 7.13 mm)
Diaphragm Material
- Isolating Diaphragm: PTFE
Duty Cycle
- 100 % Continuous Rating - Actuator
Electrical Connectors
- Cable Plug DIN 43 650 Form B, 0-250 V - Actuator
- Cable Plug: Screw Terminal, Max.
- Flying Leads 11.8” (299.72 mm) - Actuator
Enclosure, Body Material
- Cable Plug: Polyamide (PA)
- Coil: Epoxy
- Tefzel (ETFE)
Gasket Material
- Isolation between Cable Plug & Coil: Gasket (NBR)
Materials of Construction
- Contact Material: Brass, Tinned
Mounting Position
- Preferably with Solenoid System Upright - Valve
Operating Voltages
- 12 Vdc - Actuator
- 24 Vdc - Actuator
Orifice Size
- 0.062” to 0.093” (1.57 to 2.36 mm) - Valve
Process Temperature
- -10° to 70° C (14° to 158° F) - Valve
Resistance
- Cable Plug (Contact Resistance): ≤ 4 milliohms
Response Time
- Opening, Closing: Approximately 20 milliseconds - Valve
Temperature Range
- Cable Plug: -30° to 90° C (-22° to 194° F)
Tolerance
- Voltage Tolerance: ± 10 % - Actuator
UNF/UNC Connection
- 1/4”-28 UNF Female - Valve
Voltage
- Cable Plug (Nominal Voltage): 0-250 V (Standard)