ME2X System Control Unit

Brand: Burkert Fluid Control Systems

The System Control Unit (SCU) of Type ME2X is the central control unit for Bürkert devices (valves, sensors, mass flow controller or displays), which are based on EDIP (“Efficient Device Integration Platform”). 

The basic version of Type ME2X consists of power-in and power-out modules of Type ME29 and a fieldbus coupler of Type ME23. 

This fieldbus coupler transmits the internal CANopen based communication of the Bürkert field devices to industrial standards for Industrial Ethernet and fieldbus. Additionally I/O modules from Type ME24 for Analog and digital signals can be used to expand the system. Through these standard signals other field devices without a fieldbus interface can be integrated. 

(For e.g. Analog sensors, valves etc.) With the help of the graphical programming sub-systems can be automated specifically to the customer’s needs. (For e.g. controlled mixing of gases, error monitoring through switching commands, timer switches etc.)
Features
  • Fieldbus coupler for industrial ethernet and fieldbus standards
  • Up to 128 input and 128 output variables can be assigned
  • Easy integration in the process control system ensured through system specific device description files
  • Optional: expandable with I/O modules
  • Optional: graphical programming for automation of sub-systems

Specifications

Ambient Temperature Range

  • 0° to 50° C (32° to 122° F)

Approvals & Certifications

  • NAMUR NE107

Class

  • UL Devices: Power Supply Unit Limited to Class II

Communication

  • EtherNet/IP
  • FOUNDATION Fieldbus
  • Modbus/TCP
  • PROFIBUS DP
  • PROFINET

Consumption

  • Current Consumption for Digital Output (2AO/2DO & 4DO Module): 0.7 A Per Channel
  • Current Consumption for Digital Output (2AO/2DO Module): 1 A Per Module
  • Current Consumption for Digital Output (4DO Module): 1.8 A Per Module
  • Light Diodes Power Consumption: 2 W
  • Power Consumption: < 3 W

Current

  • Internally Limited to 2 A, 48 W

Electrical Connectors

  • D-Sub 9-Pin Connector
  • M12 Plug, 5-Pin
  • Power Supply Input/Output: 6-Pin Terminal Block Male/Female

Enclosure, Body Material

  • Polycarbonate

Environmental Protection

  • Protection Class: IP20
  • Protection Class: IP65

Frequency

  • Clock Digital Output (4DO Module): 20 kHz
  • Measurement Digital Input (2AI/2AO Module): 0.5 to 2,500 Hz
  • Measurement Digital Output (2AO/2DO Module): 2,500 Hz

Indication

  • RGB-LED based on NAMUR NE107

Input

  • Analog Input: 0-10 V
  • Analog Input: 0-20 mA
  • Analog Input: 4-20 mA
  • Digital Input: 0-35 Vdc

Input Impedance

  • Analog Input: 110 ohms at Current
  • Analog Input: 120 kiloohms at Voltage
  • Digital Input: 3 to 5 kiloohms at Voltage of 5 to 35 V

Loop Impedance

  • Maximum

Mounting Position

  • Horizontal
  • Vertical on Top Hat Rail EN 50022

Operating Voltages

  • 18-35 Vdc

Output

  • Analog Output: 4-20 mA

Resolution

  • Analog Output (2AO/2DO Module): 6 µA

Response Time

  • Sampling Analog Output: 100 milliseconds

Supply Voltage

  • 20-30 V over the Backplane BEF1

Voltage

  • Switching Threshold: VOFF < 2 Vdc
  • Switching Threshold: VON 5 to 35 V

Documentation