8081 Flowmeter for Water Continuous Measurement
Brand: Burkert Fluid Control SystemsThe Type 8081 ultrasonic flowmeter is intended for the measurement of water flows which may be slightly charged with contaminants.
It consists of an electronic module and a brass fitting with a built-in measuring tube. It enables a control loop to be established.
The electrical connection is made via an 5-pin M12 fixed connector.
Features- Ultrasonic flowmeter using transit time method
- Dynamic range ≥ 1:250
- Low pressure drop
- No flow-settling section necessary in the inlet and/or outlet
Specifications
Accuracy
- Flowrate: ≤ (0.01 % of Full Scale + 2 % of Measuring Value)
Ambient Temperature Range
- Operating & Storage: 5° to 55° C (41° to 131° F)
Approvals & Certifications
- EMC: EN 61000-6-3, EN 61000-6-2
- PED 97/23/CE
- Calibration Certificate
- Test Report 2.2 Certificate
BSP Connection
- G 1” Male
- G 1-1/4” Male
- G 3/4” Male
Circuit Protection
- Short Circuit: Protected for Transistor Output
Consumption
- Current - Consumption with Load: < 1 A
- Current - Own Consumption: < 4 mA
Cover Material
- PPS
Current
- 4-20 mA
Diameter
- Pipe: 1/2 to 1” (DN 15 to DN 25)
Electrical Connectors
- 1.5 mm², Max.
- 5-Pin M12 Male Fixed Connector for Female 5-Pin M12 Cable Plug
Electrical Protection
- Voltage Peak: Protected
Enclosure, Body Material
- PPS
Environmental Protection
- IP65
Humidity
- ≤ 80 % Relative Humidity, Non-Condensing
K-Factor
- Scaling Pulse (Transistor): 100 Pulse/Litre - Version QN 6.0
- Scaling Pulse (Transistor): 200 Pulse/Litre - Version QN 2.5 - 3.5
- Scaling Pulse (Transistor): 500 Pulse/Litre - Version QN 0.6 & 1.5
Loop Resistance
- 1,100 ohms at 36 Vdc, Max.
- 100 ohms at 12 Vdc, Max.
- 610 ohms at 24 Vdc, Max.
Materials of Construction
- Fixed Connector M12: Polyamide (PA)
Measuring Range
- 0.06 to 200 L/minute
NPT Connection
- 1” NPT Male
- 1-1/4” NPT Male
- 3/4” NPT Male
Output
- 4-20 mA
- Pulse (Transistor): 5-700 mA
- Version without Current Output (NPN): 0.2-36 Vdc
Output Format
- Open Collector
Power Supply
- 12-36 Vdc
Pressure Range
- psi: 0 to 232.16 (kPa: 0 to 1,600, bar: 0 to 16)
Process Temperature
- 5° to 90° C (41° to 194° F)
Repeatability
- ≤ 1 %
Reverse Polarity Protection
- Protected Against Reverse Polarity of DC
Seat / Seal Material
- Seal: EPDM
- Seal: Silicone
Shock
- EN 60068-2-27
Switch Type
- Transistor (NPN & PNP)
Vibration
- EN 60068-2-6
Wetted Materials
- Fitting: Brass
- Measuring Tube: PES