x|act i Pressure Transmitter

Brand: BD Sensors

The precise pressure transmitter x|act i has been especially designed for the food / beverage, pharmaceutical industry and biotechnology and measures vacuum, gauge and absolute pressure of gases, steam and fluids psi: 0 to 580.2 (kPa: 0 to 4,000, bar: 0 to 40). 

Several process connections example thread or hygienic versions like Varivent, dairy pipe and Clamp with a flush welded diaphragm are available, which can be combined with a cooling element for media temperatures 0° to 300° C (0° to 572° F). 

The robust stainless steel globe housing has a high ingress protection IP67 and all characteristics for a residue-free and antibacterial cleaning.
Features
  • Turn-down 1:10
  • Hygienic version
  • Flush welded diaphragm
  • Several process connections (G1" cone, Clamp, dairy pipe, etc.) (G1" cone, Clamp, dairy pipe,etc.)
  • With integrated display and operating module
  • HART®-communication
  • Cooling element for media temperatures up to 300 °C

Specifications

Approvals & Certifications

  • CE
  • EHEDG
  • EMC: Emission & Immunity According to EN 61326, 2004/108/EC
  • FDA
  • IBExU 05-ATEX-1106 x for AX12-x|act I
  • IEC 60770
  • TÜV

BSP Connection

  • G 1”

Diaphragm Material

  • 316L Stainless Steel
  • Hastelloy C-276
  • Tantalum

Enclosure, Body Material

  • 304 Stainless Steel

Environmental Protection

  • IP67

Fill Material

  • Filling Fluids: Halocarbon
  • Filling Fluids: Silicon Oil

Flange Size - 1” (DN 25)

  • 1” (DN 25) - PN 40

Flange Size - 2” (DN 50)

  • 2” (DN 50) - PN 40

Flange Size - 3” (DN 80)

  • 3” (DN 80) - PN 16

Output

  • 4-20 mA, 2-Wire

Pipe Connection

  • 1” Pipe (DN 25)
  • 1-1/2” Pipe (DN 40)
  • 2” Pipe (DN 50)

Pressure Range

  • bar: -0.4 to 40
  • kPa: -40 to 4,000
  • psi: -5.80 to 580.2

Pressure Type

  • Absolute
  • Gauge

Tri-Clamp Connection

  • 1” Tri-Clamp (DN 25)
  • 1-1/2” Tri-Clamp (DN 32)
  • 2” Tri-Clamp (DN 50)
  • 3/4” Tri-Clamp

  • Medical Technology
  • Food and Beverage

show more