Ambient Temperature Range
- Operation & Storage: 0° to 60° C (32° to 140° F)
Approvals & Certifications
- CE
- EU Directives
- PED 2014/68/EU
Compensated Temperature
- Temperature Measurement: Automatic (Integrated Pt1000) - Reference Temperature 25° C (77° F)
Diameter
- Pipe: 0.59 to 7.8” (15 to 200 mm)
Electrical Connectors
- 4 x 0.2 to 1.5 mm² Shielded
- Cable Plug EN 175301-803
Humidity
- ≤ 80 % Relative Humidity, Non-Condensing
Materials of Construction
- Electrode: Stainless Steel for Cell Constant C= 0.01 or 0.1
- Graphite for Cell Constant C= 1.0 or 10
Measuring Error
- Conductivity Measurement Deviation - Typical: 3 to 5 % of Measured Value
- Temperature Measurement Deviation: ± 1° C (1.8° F)
Measuring Range
- Conductivity Measurement: 0.05 to 200,000 µS/cm
Pipe Connection
- DN 100 Pipe
- DN 15 Pipe
- DN 20 Pipe
- DN 25 Pipe
- DN 32 Pipe
- DN 40 Pipe
- DN 50 Pipe
- DN 65 Pipe
- DN 80 Pipe
Plug Material
- Cable Plug: Polyamide (PA)
Pressure Range
- psi: 0 to 145 (kPa: 0 to 1,000, bar: 0 to 10) - Max.
Process Temperature
- PP: 0° to 80° C (32° to 176° F)
- PVC: 0° to 50° C (32° to 122° F)
- PVDF, Stainless Steel, Brass: 0° to 100° C (32° to 212° F)
Resolution
- Temperature Measurement: 0.1° C
Sensor, Probe Material
- Pt1000: 316Ti Stainless Steel 1.4571
Temperature Range
- Measuring Range: -50° to 150° C (-58° to 302° F)
Welded Connection
- DN 100 Weld End
- DN 125 Weld End
- DN 150 Weld End
- DN 200 Weld End
- DN 50 Weld End
- DN 65 Weld End
- DN 80 Weld End
Wetted Materials
- Fitting, Sensor Holder: PVDF
- Fitting: 316L Stainless Steel, 1.4404
- Fitting: Brass
- Fitting: Polypropylene (PP)
- Fitting: PVC