CamCor PRO Coriolis Flow Meter & Transmitter

Brand: Cameron

Equipped with a sophisticated transmitter (including a self diagnostics feature, large display, and field configurability via keypad), the Cameron PRO Series are cost-effective processgrade Coriolis flow meters.
Features
  • Extensive Self-Diagnostic Capabilities (Connection Faults, Pipeline Variations, Media Pulsation, etc.)
  • Configurable via Keypad or Digital Communications
  • Fast Response and Calculation Frequency
  • User-Configurable Alarms
  • Dual Independent Pulse Outputs, Dual Independent Current Outputs, One Status Output and One Status Input
  • Enhanced Maintenance Functions (Event/user Change Logging and Downloads, Recoverable Factory Configuration and Calibration, etc.)
  • Compatible with Modbus and HART Communication Protocols

Specifications

Brand

Ambient Temperature Range

  • -40° to 55° C (-40° to 131° F)

Applications

  • Oil & Gas Production Sites

Approvals & Certifications

  • ATEX: 94/9/EC, EN 60079-0: 2012, EN 60079-1: 2007, EN 60079-11: 2012
  • CSA: Class I, Zone 1, Ex d Ib IIB T4 Gb
  • EMC Directive: 2004/108/EC, EN 55011: 1998, A1, 1999, A2: 2002, Group 1, Class B, EN 61000-6-2: 2001, EN061326-1: 2006
  • IEC Ex: IEC 60079-0: 2011, IEC 60079-1: 2007-04, IEC 60079-11: 2011

Cable Length

  • Remote Communication Cable: 16.4 feet (5 metres)

Communication

  • Baud Rate: 9,600, 19,200, 38,400 bit/sec
  • HART: Protocol Version 7, Hybrid Bell 202
  • Modbus ASCII/RTU
  • RS-485

Conduit Connection

  • 3/4” NPT Female

Configuration

  • Integral - Transmitter Configuration
  • Separately Mounted - Transmitter Configuration

Consumption

  • Maximum

Density Range

  • 0.3 to 2 G/mL - Metering Range (Liquid)

Display

  • 2 LEDs (Green & Red)
  • Backlight Display (White, Orange)
  • LCD Display (128 x 64 Pixels)

Electrical Connectors

  • Minimum Conductor Size: 18 AWG

Enclosure Finish

  • Paint Color: Light Gray (RAL7035)
  • Paint Typical: Baked Enamel

Enclosure, Body Material

  • 304 Stainless Steel

Environmental Protection

  • Dust-Proof
  • Explosion-proof
  • IP66
  • IP67
  • Water-Proof

Flange Size - 1-1/2” (DN 40)

  • 1-1/2” (DN 40) - 150# ASME /ANSI
  • 1-1/2” (DN 40) - 300# ASME /ANSI
  • 1-1/2” (DN 40) - 600# ASME /ANSI

Flange Size - 1” (DN 25)

  • 1” (DN 25) - 150# ASME /ANSI
  • 1” (DN 25) - 300# ASME /ANSI
  • 1” (DN 25) - 600# ASME /ANSI

Flange Size - 1/2” (DN 15)

  • 1/2” (DN 15) - 150# ASME /ANSI
  • 1/2” (DN 15) - 300# ASME /ANSI
  • 1/2” (DN 15) - 600# ASME /ANSI

Flange Size - 2” (DN 50)

  • 2” (DN 50) - 150# ASME /ANSI
  • 2” (DN 50) - 300# ASME /ANSI
  • 2” (DN 50) - 600# ASME /ANSI

Flange Type

  • Raised Face (RF)

Flow Rate

  • 0.106 to 8.46 gpm (0.40 to 32 LPM) - Guaranteed Min. Volumetric Flow Rate
  • 0.264 to 21.2 gpm (1 to 85.2 LPM) - Min. Setting of Volumetric Flow Rate
  • 0.88 to 70.5 lbs/min - Guaranteed Min. Mass Flow Rate
  • 2.2 to 176 lbs/min - Min. Setting of Mass Flow Rate
  • 2.64 to 212 gpm (10 to 802.5 LPM) - Max.
  • 22 to 1,764 lbs/min - Max.
  • 44.1 to 3,527 lbs/min - Max.
  • 5.29 to 423 gpm (20 to 1,601 LPM) - Max.

Media

  • Liquids - Applicable Fluid

Mounting Position

  • Horizontal Piping
  • Vertical Piping

NPT Connection

  • 1/2” NPT Female
  • 3/4” NPT Female

Output

  • 1.5 V
  • 10-30 V Min. - Pulse Output
  • 13 V Min. - Pulse Output
  • 4-20 mA DC, Max.
  • 50 mA DC

Output Format

  • Pulse Output

Output Impedence

  • 2.2 kiloohms

Power Requirement

  • 100-240 Vac, 50/60 Hz - Safety Rated

Power Supply

  • 20-30 Vdc
  • 85-264 Vac 50/60 Hz

Range

  • Transmission Length: Max.

Repeatability

  • ± 0.1 % of Reading (± 1/2 of Zero Stability)

Resistance

  • Analog Output Load Resistance: 600 ohms
  • Pulse Output ON Resistance: ≥ 0.6 ohms

Response Time

  • 25 to 50 milliseconds

Sensor, Probe Type

  • Infrared

Size

  • Nominal Size: 1/2” to 2” (12.7 to 51 mm)

Stability

  • 0.0033 to 0.265 lbs/min - Zero Stability

Temperature Range

  • -40° to 125° C (-40° to 257° F)

Tri-Clamp Connection

  • 1” IDF Ferrule
  • 1/2” IDF Ferrule
  • 1-1/2” IDF Ferrule
  • 2” IDF Ferrule

Uncertainty

  • ± 0.003 G/mL - Uncertainty of Density (Liquid)
  • ± 0.1 % of Full Scale - Analog Output Uncertainty
  • ± 0.2 % of Reading (± Zero Stability) - Uncertainty of Flow Rate

Wetted Materials

  • 316L Stainless Steel
show more