Adjustment Type
- Factory Set (Pre-Set) One Switch
- Set Point Adjustment
Ambient Temperature Range
- -18° to 71° C (0° to 160° F) with Buna-N Construction
- -18° to 82° C (0° to 180° F) with Viton Construction
Applications
- Balers & Lube Oil Systems
- Compactors
- Industrial Applications
- Mobile Hydraulics Units
- OEM Applications
Approvals & Certifications
Approvals & Certifications
- ATEX Directive (94/9/EC) II 1 G EEx ia IIC T6 Tamb: -50° to 60° C (-58° to 140° F)
- CE
- CRN
- CSA C22.2 No. 14, File # E42272
- GOST-R 51330.0, 51330.1, 51330.10 & 51330.14
- Low Voltage Directive (LVD) 73/23/E & 93/68/EEC
- PED: 97/23/EC
- UL (C,US) 508
Deadband
- psi: 20 to 950 (kPa: 137.9 to 6,550, bar: 1.4 to 65.5)
Electrical Connectors
- 0.11” Push-On Terminals
- 18 AWG
- 22 AWG
Electrical Contacts
- Gold Flashing over Silver Contact for Loads down to 5 mA at 6 Vdc, 2 mA at 12 Vdc & 1 mA at 24 Vdc
- Normally Closed
- Normally Open
Electrical Rating
- 0.5 A Resistive, 0.25 A Inductive at 125 Vdc
- 5 A at 250 Vac
- 5 A Resistive, 3 A Inductive at 30 Vdc
- 5 A Resistive, 5 A Inductive (75 % Power Factor), at 125/250 Vac, 1/4 hp
Name Plate, Tag Material
- Stainless Steel ID, Paper Tag & Wire Attachment
Overpressure & Static Pressure Limits
- Over Range Pressure - psi: 8,000 to 10,000 (kPa: 55,158 to 68,948, bar: 551.6 to 689.5)
Process Connection Material
Proof Pressure
- psi: 10,000 to 12,000 (kPa: 68,948 to 82,737, bar: 689.5 to 827.4)
Repeatability
- Set Point Repeatability: ± 1.5 % of Full Scale Range
Service
- Oxygen Service Cleaning, Alcohol Cleaning to Remove Residue from the Process Connection
Set Point - Decreasing
- bar: 6.9 to 517.1
- kPa: 689.5 to 51,711
- psi: 100 to 7,500
Set Point - Increasing
- bar: 6.9 to 517.1
- kPa: 689.5 to 51,711
- psi: 100 to 7,500
Shock
- Set Point Repeats after 50 G, 10 millisecond Duration
Storage Temperature
- -40° to 82° C (-40° to 180° F)
System Pressure
- bar: 689.5
- kPa: 68,950
- psi: 10,000
Vibration
- Set Point Repeats after 10 G, 5 to 500 CPS