Flow Capacity at 100 psig Supply, 80 psig Outlet
- 1/4”: 80 scfm (37.8 m³/s)
- 3/8”: 80 scfm (37.8 m³/s)
Operating Pressure Range
- Primary - Max.: 250 psig (17.2 bar)
Operating Temperature
- -40° to 160° F (-40° to 71° C) Temperatures below (0° C) 32° F Require moisture-free Air
Effect of Supply Pressure Variation
- Less than 0.1 psig for 100 psig (6.89 bar) change
Exhaust (Relief) Capacity
- 4 scfm with downstream Pressure 5 psig above set Pressure. Exhaust commences at 0.01 psig above set Pressure.
Gauge Ports (2x) Can be Used as Additional Full Flow 1/4” Outlet Ports
Response
- 250 ms (The valve will open to full flow and fill a volume of 1250 cm³)
Constant Bleed Rate
- 1.0 to 12.5 SCFH (Depending on output Pressure)
Repeatability / Sensitivity
- ± 0.010 psig (± 0.00068 bar)