Ambient Temperature Range
Approvals & Certifications
Cable Length
- Electrical Connection: 1.64 feet (0.5 Meter)
Duty Cycle
- 100 % Duty Cycle Continuous Rating
Electrical Connectors
- 2 FEP Flying Leads
- Spade Connector According to DIN 43650 C for Cable Plug
Electrical Contacts
- Normally Closed
- Normally Open
Enclosure, Body Material
- Actuator: Polyphenylene Sulfide (PPS)
- Fluid: ETFE
- Fluid: PEEK
- Fluid: PVDF
Environmental Protection
- IP40 with Rectangular Plug
- IP65 with Flying Leads or with Cable Plug
Flow Rate
- Water: 0.03 to 0.05 m³/hour (Kv)
- Water: 0.035 to 0.058 gpm (Cv)
Materials of Construction
- Coil: EPOXID
- Manifold: PEEK
Media
- Aggressive Liquids & Gases
Mounting Position
- Preferably with Actuator Upright
Orifice Size
- 0.03” to 0.06” (0.8 to 1.6 mm)
Pressure Range
- Vacuum - psi: -29 (kPa: -200, bar: -2)
Process Temperature
- 0° to 50° C (32° to 122° F) Depending on Orifice & Seal Material
Response Time
- Opening, Closing: 25 milliseconds (Pressure Rise 0 to 10 %, 100 to 90 %)