Accuracy
- Indication Accuracy: ± 1 % of Adjustable Range
Adjustment Type
- Factory Set (Pre-Set) Two Switches
- Set Point Adjustment
Ambient Temperature Range
- -40° to 71° C (-40° to 160° F), Set Point Typically Shifts less than 1 % of Range for a 28° C (50° F) Ambient Temperature Change
Applications
- Food Service Appliances
- HVac Equipment
- Ovens
- Packaging Machines
- Process Plants
Approvals & Certifications
- ATEX Ex directive (94/9/EC) II 2 G Ex d IIC T6, II 2 D Ex TD A21 IP66 T 85° C (185° F), Tamb: -40° to 75° C (-40° to 167° F)
- CE 0539
- CQST Exd IIC T6 DIP A21 TA 85° C (185° F), Tamb: -40° to 75° C (-40° to 167° F)
- CSA C22.2 No. 24, File # LR7814
- GOST-R 51330.0, 51330.1, 51330.10 & 51330-14
- Low Voltage Directive (LVD) 73/23/EC & 93/68/EEC
- RTN
- UL (C,US) 50 & 698 Class I, Divisions 1 & 2, Groups B, C, D, Class II, Divisions 1 & 2, Groups E, F, G, Class III, Class I, Zone 1, Groups IIB + H₂ T6
Approvals & Certifications
Deadband
- Temperature Deadband: Typically 1 % of Range Under Laboratory Conditions (21.11° C (70° F) Circulating Bath at Rate of 0.5° F Per Minute Change)
Electrical - Free Leads
- 18 AWG, 1.19 mm² Color-Coded Leadwires, Approximately 9” (228.6 mm) Exposed with Strain Relief
Electrical Connectors
- 7/8” Diameter Knockout on Left Hand Side
- Plug Connection
- Two 3/4” NPT with Terminal Block
Electrical Contacts
- Gold
- Normally Closed
- Normally Open
Electrical Rating
- 1 A at 125 Vac Resistive
- 10 A at 125 Vdc or Vac Resistive, Deadband & Min. Set Point May Increase
- 15 A at 125/250/480 Vac Resistive
- 20 A at 125/250 Vac Resistive
- Close Deadband, 5 A at 125/250 Vac Resistive
Enclosure, Body Material
- Gasketed Die Cast Aluminum
Environmental Protection
- Flameproof
- IP66
- NEMA 4X
- NEMA 7
- NEMA 9
Materials of Construction
- Faceplate: Lexan
- Thermowell: 316 Stainless Steel
- Union Connector & Thermowell: Brass
- Union Connector: 304 Stainless Steel
Name Plate, Tag Material
- Stainless Steel, Paper ID Tag & Wire Attachment
Process Connection Material
Repeatability
- Set Point Repeatability: ± 1 % of Adjustable Range
Service
- Oxygen Service Cleaning, Alcohol Cleaning to Remove Residue from the Process Connection
Set Point - Decreasing
- -117.8° to 343.3° C (-180° to 650° F)
Set Point - Increasing
- -117.8° to 343.3° C (-180° to 650° F)
Shock
- Set Point Repeats after 15 G, 10 millisecond Duration
Storage Temperature
- -54° to 71° C (-65° to 160° F)
Switch Type
- Dual Switch may be separated up to 100 % of Range
- Two SPDT
Vibration
- Set Point Repeats after 2.5 G, 5 to 500 Hz