6164 3/2-Way Cartridge Solenoid Valve

Brand: Burkert Fluid Control Systems

Type 6164 was developed with the goal, to simplify pneumatic control with optimum integration of a pilot valve in block and plastic moulding parts. Thus, making a more compact design possible. 

This valve sets new standards with its uncompromising reliability, above average life cycle span and excellent fluidic characteristics. 

Various certifications and conformities make the use of the valve in medical applications such as media multiplexers in dental technology and oxygen control in respirators possible.
Features
  • Compact design with 11 mm width per station
  • High durability and reliability
  • Low power consumption, as well as optional ATEX Ex ib version
  • Design for optimum integration

Specifications

Ambient Temperature Range

  • FKM: -10° to 55° C (14° to 131° F)
  • Low Temperature Version: -20° to 55° C (-4° to 131° F)

Approvals & Certifications

  • BVS 16-ATEX-E 088 X: II 2 G Ex Ib IIC T6-T4 Gb, II 2D Ex Ib IIIB T1 55° C Db
  • IECx PTB 07.0063
  • UL Class 2

Consumption

  • Power: 0.3 W - Exi Version
  • Power: 0.7 W
  • Power: 2.8 W / 0.3 W - with External Electric Power Reduction

Current

  • Holding Current: 23-29 mA Min.

Duty Cycle

  • 100 % Duty Cycle Continious Rating

Electrical Connectors

  • Flying Leads
  • Plug Connection
  • Soldering Connection

Electrical Contacts

  • Normally Closed
  • Normally Open

Enclosure, Body Material

  • Coil: AISI 434 Stainless Steel (1.4113)
  • PEEK

Environmental Protection

  • Leads: IP54
  • Pins: IP00
  • Special Plug: IP40

Frequency

  • Switching Noise: 42 dB - According to ISO 3745, Testing Environment in Brass Manifold, Free-Hanging
  • Switching: 16 Hz

Materials of Construction

  • Core: AISI 434 Stainless Steel (1.4113)
  • Fitting: Brass
  • Seal Switch: Polyamide

Media

  • Neutral Gases

O-Ring Material

  • FKM

Operating Voltages

  • 12 Vdc
  • 24 Vdc

Orifice Size

  • 0.01” to 0.04” (0.5 to 1.2 mm)

Pressure Drop

  • Permissible Leakage (Vacuum): psi: -145 (kPa: -1,000, bar: -10)

Pressure Range

  • Vacuum - psi: -130.5 to -21.7 (kPa: -900 to -150, bar: -9 to -1.5)

Process Temperature

  • FKM: -10° to 55° C (14° to 131° F)
  • Low Temperature Version: -20° to 55° C (-4° to 131° F)

Resistance

  • Nominal Coil: 320 to 510 ohms ± 4 %

Response Time

  • Open, Close (Pressure Rise 0-10 %, 100-90 %): < 5 milliseconds

Seat / Seal Material

  • Seal: FKM

Solenoid Type

  • 3/2-Way

Spring Material

  • AISI 301 Stainless Steel 1.4310

Tolerance

  • Volatge: ± 10 %

  • Medical applications

show more